Parking Floor

Magnetic sensor for monitoring the occupation of parking space

A version of the Parking Sensor drowned in the asphalt, which is used in cases where it is not possible to drill holes in the road surface. Has the same features and guarantees the same performances and applications.

Connection


Network

Radio 868 Mhz ISM band, GFSK modulation, 115 kbps bit rate, TX out 13 dbm RX -110 sensitivity, dbm. 128-bit AES encryption. Free range 350 m LOS

Setup device

RX system 433 Mhz passive, OOK modulation, Range of connection 10 cm

Technical Features

Power source Lithium primary battery 1xAA 3.6 V
Consumption 5 µA sleep: receiving setup commands, 35 mA riception of data , 180 mA data transmission
Average lifetime 5-10 years old (monitoring frequency 2 min and 5 min transmission frequency) depending on the number of batteries installed
Installation mode Fixed to the ground with two screws
Container characteristics Metal container
Dimensions 110x90x30 mm